Cloud Initiative Reference Solution

OPC Foundation Cloud Initiative Open-Source Reference Solution

Table of Contents

Reference Edge Hardware

The reference solution is validated on a compact, fanless industrial PC built around the Raspberry Pi Compute Module 5 (CM5). This platform provides an industrial-grade, DIN-rail-mountable edge gateway suitable for running the OPC Foundation Cloud Initiative open-source reference workloads.

Waveshare IPCBox-CM5

Bill of Materials (Purchasing)

Purchase the following components from Waveshare as a complete kit:

# Component Description Product Page
1 IPCBox-CM5-A Industrial computer / enclosure kit for the Raspberry Pi Compute Module 5 (aluminum-alloy passive-cooling case, carrier board, dual Gigabit Ethernet, USB, dual HDMI, M.2 M-Key NVMe slot, wide-voltage DC input, RTC). https://www.waveshare.com/ipcbox-cm5-a.htm
2 Raspberry Pi Compute Module 5 The system-on-module (BCM2712 quad-core Cortex-A76). Select a variant without eMMC (not needed), a minimum of 8GB RAM and optionally WiFi to match your needs. https://www.waveshare.com/compute-module-5.htm
3 SK NVMe 2242 128G SSD (M.2) 128 GB M.2 2242 NVMe SSD used for the operating system and application data storage. https://www.waveshare.com/sk-nvme-2242-128g-ssd-m.2.htm
4 USB-to-M.2 (NVMe) adapter / enclosure A USB 3.x adapter that accepts an M-Key M.2 NVMe SSD (2242 compatible). Used to connect the SSD to a separate PC so it can be imaged with Raspberry Pi Imager before final assembly. https://www.waveshare.com/usb-to-sata.htm

Software Installation (Imaging the SSD)

The operating system is written to the NVMe SSD from a separate PC using the USB-to-M.2 adapter and Raspberry Pi Imager. Do this before assembling the unit.

  1. Insert the SSD into the USB-to-M.2 adapter. Seat the SK NVMe 2242 128G SSD in the adapter's M-Key slot and secure it, then plug the adapter into a USB 3.x port on your PC. The drive should enumerate as a USB mass-storage device.
  2. Install Raspberry Pi Imager on the PC from https://www.raspberrypi.com/software/ and launch it.
  3. Select Device: Pick Raspberry Pi 5.
  4. Select OS: Click Raspberry Pi OS (other) and pick Raspberry Pi OS Lite (64-bit).
  5. Select Storage: Pick the SK NVMe SSD presented through the USB-to-M.2 adapter.

    ⚠️ Double-check you are selecting the SSD and not another drive on your PC — imaging is destructive and erases the selected device.

  6. Customization: Set the hostname, username/password, Wi‑Fi (if used), locale/timezone, and enable SSH on the Services tab. This allows a fully headless first boot.
  7. Writing: Click WRITE and wait for Imager to write and verify the image.
  8. Finish: Close the imager, eject the adapter, remove the SSD, and proceed to the Hardware Installation to assemble the device.

Hardware Installation

Safety: Power off and disconnect the DC input before opening the case. Work on an anti-static surface and handle the CM5 and SSD by their edges.

Image the SSD first. Complete the Software Installation steps below to write Raspberry Pi OS onto the NVMe SSD using the USB-to-M.2 adapter before installing the SSD into the enclosure.

  1. Open the enclosure. Remove the screws securing the IPCBox-CM5-A cover to expose the CM5 carrier board and the M.2 slot.
  2. Install the (already-imaged) NVMe SSD. Insert the SK NVMe 2242 128G SSD into the M.2 M-Key slot at roughly a 30° angle, press it down flat, and secure it with the provided M.2 standoff screw.
  3. Install the Compute Module 5. Align the two high-density connectors on the CM5 with the mating connectors on the carrier board and press firmly and evenly until the module seats fully. Fasten the CM5 mounting screws.
  4. Apply the thermal interface. Ensure the thermal pad between the CM5 SoC and the aluminum case/heat spreader is in place so the enclosure can act as a passive heatsink.
  5. Reassemble the enclosure and reinstall the cover screws.
  6. Connect peripherals. Attach the Ethernet cable, and (optionally, for first-time console access) an HDMI monitor and USB keyboard.
  7. Connect power. Wire the DC input within the enclosure's rated voltage range (7V to 36V, so a 24V industrial power supply is ideal, or simply use the supplied AC/DC adapter for bench testing) to the power terminal / jack and switch it on. The power/status LED should illuminate and the device will boot from the NVMe SSD.

First-Boot Configuration

  1. Power on the assembled device and log in (via the HDMI/keyboard console or over SSH using the hostname/credentials configured during imaging):
    ssh <username>@<hostname>.local
  2. Update the system:
    sudo apt update && sudo apt full-upgrade -y
  3. Verify the NVMe SSD is the active root device and the CM5 memory is detected:
    lsblk
    free -h
  4. Confirm network connectivity on the built-in Gigabit Ethernet:
    ip addr
    ping -c3 opcfoundation.org

Deploying the IoT Stack

The reference workload is defined in iot-stack.yaml and runs on a lightweight single-node Kubernetes cluster (K3s) on the CM5.

What the Stack Contains

iot-stack.yaml deploys the following components, forming an end-to-end pipeline from industrial protocols to a time-series database:

Component Image Role Ports
ua-edgetranslator ghcr.io/opcfoundation/ua-edgetranslator:main OPC Foundation UA Edge Translator — connects to southbound assets and translates protocols (LoRaWAN, OCPP, etc.) into an OPC UA information model. Exposes a web UI for configuration. 4840 (OPC UA server), 5000/5001 (LoRaWAN), 19520/19521 (OCPP), 8080 (web UI)
ua-cloudpublisher ghcr.io/barnstee/ua-cloudpublisher:main UA Cloud Publisher — subscribes to OPC UA data (from the edge translator) and publishes it as OPC UA PubSub JSON messages to the MQTT broker. Exposes a web UI for configuration. 8081 (web UI)
ua-cloudcommander ghcr.io/opcfoundation/ua-cloudcommander:main OPC Foundation UA Cloud Commander — the command & control Responder. Subscribes to the Mosquitto commands/# topic for ua-action-request messages, executes OPC UA operations (Read, HistoricalRead, Write, MethodCall) against on-premises OPC UA servers (e.g. the Edge Translator), and publishes ua-action-response messages back to the responses topic. Has no web UI.
mosquitto eclipse-mosquitto:2.0.18 Eclipse Mosquitto MQTT broker that carries the OPC UA PubSub data/# and metadata messages between the publisher and Telegraf. Configured via mosquitto-conf (TLS + authentication required with the IOT_USERNAME / IOT_PASSWORD credentials supplied at apply time, exposed to the broker via the MOSQUITTO_USERNAME / MOSQUITTO_PASSWORD env vars, TLS listener on 8883). 8883 (MQTT/TLS)
telegraf telegraf:1.37-alpine Telegraf agent that consumes the MQTT PubSub messages, parses them with the json_v2 parser (defined in the telegraf-conf ConfigMap), and writes them into InfluxDB. Measurements: opcua_pubsub (data) and opcua_metadata (metadata).
influxdb influxdb:2.7 InfluxDB 2.7 time-series database that stores the ingested telemetry. Initialized with org iot, bucket mqtt, and admin user set to your IOT_USERNAME. Exposes a web UI (Data Explorer / dashboards). 8086 (web UI/API)
grafana grafana/grafana:11.2.0 Grafana — dashboarding & alerting UI with a pre-provisioned InfluxDB data source (Flux, org iot, bucket mqtt) and a starter dashboard ("OPC UA Telemetry Overview"). 3000 (web UI)
ua-cloudaction ghcr.io/opcfoundation/ua-cloudaction:main OPC Foundation UA Cloud Action — the command & control Requestor. Polls a configured InfluxDB field and, when it crosses a threshold, publishes a ua-action-request (MethodCall) to the Mosquitto commands topic for UA Cloud Commander to execute, closing the digital feedback loop. Has a status web UI and implements the OPC UA Web API for app access. 8082 (web UI)
portainer portainer/portainer-ce:2.21.4 Portainer CE — web UI to manage the single-node K3s cluster (workloads, logs, shells, events). Runs with a cluster-admin-bound ServiceAccount so it manages the cluster in-cluster via the K3s API server. 9443 (HTTPS UI), 9000 (HTTP UI), 8000 (edge tunnel)
influxdb-auth (Secret) Holds the INFLUX_TOKEN used by InfluxDB (admin token), Telegraf (write token), Grafana (query token), and UA Cloud Action (query token). Provided at deploy time via the ${INFLUX_TOKEN} variable.
telegraf-conf / mosquitto-conf (ConfigMaps) Configuration for Telegraf (MQTT inputs + InfluxDB output) and Mosquitto respectively.
ua-cloudpublisher-settings (ConfigMap) Pre-populated settings.json seeded into the UA Cloud Publisher on first start (broker connection, topics, and OPC UA metadata), so no manual broker configuration is required.

Data flow:

Reference solution architecture and data flow

Security note: you choose the credentials at deployment time via the IOT_USERNAME / IOT_PASSWORD variables (see Apply the Stack Manifest), used consistently across the Edge Translator, Cloud Publisher, Cloud Commander, Mosquitto, and InfluxDB for demo purposes. Mosquitto uses a self-signed TLS certificate generated at pod startup. Change these and use certificates from a trusted CA before any production or exposed deployment.

Install K3s on the Pi

Once the device has booted and been updated, install K3s (SSH into the device first):

# Install a single-node K3s cluster (server + agent on the same node)
curl -sfL https://get.k3s.io | sh -

# Verify the node is Ready (may take ~30s)
sudo k3s kubectl get nodes

To use the standard kubectl command and the KUBECONFIG without sudo:

mkdir -p ~/.kube
sudo cp /etc/rancher/k3s/k3s.yaml ~/.kube/config
sudo chown "$(id -u):$(id -g)" ~/.kube/config
export KUBECONFIG=~/.kube/config
echo 'export KUBECONFIG=~/.kube/config' >> ~/.bashrc

kubectl get nodes

K3s ships with the Traefik ingress controller and a built-in ServiceLB (klipper-lb) load balancer, so the type: LoadBalancer Services in the manifest are reachable directly on the node's IP address.

Apply the Stack Manifest

  1. Copy iot-stack.yaml onto the device (e.g. with git clone, scp, or by pasting it into a file opened via a text editor like nano).

  2. Provide the deployment credentials and InfluxDB token. The manifest references ${IOT_USERNAME}, ${IOT_PASSWORD}, and ${INFLUX_TOKEN}, so set them and substitute them at apply time:

    # Choose the shared username/password used by the Edge Translator,
    # Cloud Publisher, Mosquitto broker, and InfluxDB.
    # NOTE: InfluxDB requires the password to be at least 8 characters.
    export IOT_USERNAME="myUsername"
    export IOT_PASSWORD="ChangeMe123"
    
    # Generate a random InfluxDB token (or supply your own)
    export INFLUX_TOKEN="$(openssl rand -hex 32)"
    
    # Substitute ONLY these variables and apply. Restricting the variable list is
    # important so envsubst does not touch the runtime shell variables (e.g.
    # $MOSQUITTO_USERNAME) used inside the container start-up commands.
    envsubst '${IOT_USERNAME} ${IOT_PASSWORD} ${INFLUX_TOKEN}' < iot-stack.yaml | kubectl apply -f -

    envsubst is part of the gettext package (sudo apt install -y gettext-base). Keep the values you chose — you'll reuse IOT_USERNAME / IOT_PASSWORD to log into the web UIs and the broker, and the generated INFLUX_TOKEN to authenticate Telegraf and log into InfluxDB via the API.

  3. Watch the workloads come up:

    kubectl get pods -w
    kubectl get svc

    All pods should reach Running/Ready, and each LoadBalancer Service should receive an EXTERNAL-IP (the node's IP).

    If the external IP address for some Kubernetes services shows as <pending>, use the following command to assign the external IP address of the traefik service: sudo kubectl patch service -p '{"spec": {"type": "LoadBalancer", "externalIPs":[""]}}'.

Where Telemetry Data Is Persisted

The ingested OPC UA telemetry is stored by InfluxDB in the mqtt bucket. That database is backed by a Kubernetes hostPath volume, so the data lives directly on the Pi's NVMe SSD at:

/influxdb2

Because this is a host directory (not ephemeral pod storage), the telemetry survives pod restarts, redeploys, and reboots.

Related OPC UA telemetry persistence paths are also mapped as hostPath volumes on the Pi:

Path on the Pi Component Contents
/influxdb2 InfluxDB Time-series telemetry, buckets, and InfluxDB config (the primary telemetry store).
/translator/settings, /translator/nodesets, /translator/pki, /translator/logs UA Edge Translator Configuration, OPC UA nodesets, certificates, and logs.
/publisher/settings, /publisher/pki, /publisher/logs, /publisher/store UA Cloud Publisher Configuration, certificates, logs, and the Store & Forward message store (queued messages held during broker/connectivity outages).
/commander/pki, /commander/logs UA Cloud Commander OPC UA client certificates and logs.
/mosquitto Mosquitto Broker persistence database (mosquitto.db: retained messages and queued messages for persistent sessions).
/portainer Portainer Portainer database, users, and settings.
/grafana Grafana Grafana database, users, and user-created dashboards.

Note: Keep the INFLUX_TOKEN safe, to read the telemetry stored in InfluxDB in backup scenarios.

Accessing the Web UIs

Replace <device-ip> with the CM5's IP address (from ip addr or kubectl get svc). All services are exposed as LoadBalancer types on the node.

Service URL Notes
UA Edge Translator http://<device-ip>:8080 Configure southbound asset connections and the OPC UA information model. Log in with the IOT_USERNAME / IOT_PASSWORD you set (exposed via the manifest OPCUA_USERNAME / OPCUA_PASSWORD env vars).
UA Cloud Publisher http://<device-ip>:8081 Configure which OPC UA nodes to publish and the MQTT broker target (mosquitto.default.svc.cluster.local:8883, TLS). Log in with the IOT_USERNAME / IOT_PASSWORD you set (exposed via the manifest PUBLISHER_USERNAME / PUBLISHER_PASSWORD env vars).
InfluxDB http://<device-ip>:8086 Time-series UI, Data Explorer, and dashboards. Log in with the IOT_USERNAME / IOT_PASSWORD you set (org iot, bucket mqtt).
Portainer https://<device-ip>:9443 Kubernetes management UI for the K3s cluster. On first access you set the admin password (see Managing the Cluster with Portainer).
Grafana http://<device-ip>:3000 Dashboards & alerting. Log in with the IOT_USERNAME / IOT_PASSWORD you set. The InfluxDB data source and a starter dashboard are pre-provisioned (see Dashboards with Grafana).
UA Cloud Action http://<device-ip>:8082 Status UI for the automated feedback loop (data-source, broker, and Commander connectivity) and OPC UA Web API. Log in with the IOT_USERNAME / IOT_PASSWORD you set (see Automated Feedback Loop with UA Cloud Action).

To keep both UIs reachable on the single node, 8081 (mapped to the container's 8080) while the Edge Translator stays on 8080. No extra steps are needed — just browse to :8080 and :8081 respectively.

Managing the Cluster with Portainer

Portainer CE provides a web UI to inspect and manage everything running on the single-node K3s cluster (deployments, pods, logs, container shells, events, and volumes). It is deployed by iot-stack.yaml and is pre-wired to manage the cluster it runs in — no manual endpoint configuration is required.

How the K3s connection works:

  • The manifest creates a portainer-sa-clusteradmin ServiceAccount and a ClusterRoleBinding to the built-in cluster-admin role, then runs the Portainer pod under that ServiceAccount. Portainer therefore talks to the K3s API server in-cluster using the mounted ServiceAccount token — it manages the local Kubernetes environment out of the box.
  • Portainer data (users, settings) is persisted on the Pi at /portainer.

First-time setup:

  1. Browse to https://<device-ip>:9443 (accept the self-signed certificate warning) within a few minutes of the pod starting.

    For security, Portainer disables initial admin creation if you don't complete it shortly after startup. If you see a timeout message, restart the pod: kubectl rollout restart deployment/portainer.

  2. Create the admin user and password.
  3. On the environments page, select the local Kubernetes environment (already connected via the in-cluster ServiceAccount) and click Live connect.
  4. You can now browse the default namespace to see the Edge Translator, Cloud Publisher, Cloud Commander, Mosquitto, Telegraf, and InfluxDB workloads, view their logs, exec into containers, and monitor cluster resources.

Onboarding an OPC UA Device

Use this path when the device already speaks OPC UA (including data that the Edge Translator has already exposed).

  1. Open the UA Cloud Publisher UI at http://<device-ip>:8081 (log in with the IOT_USERNAME / IOT_PASSWORD you set, exposed via the manifest PUBLISHER_USERNAME / PUBLISHER_PASSWORD env vars).
  2. Go to OPC UA Connect and enter the device's OPC UA endpoint URL, e.g.:
    • The Edge Translator: opc.tcp://<device-ip>
    • A standalone OPC UA device: opc.tcp://<device-address>:<port>
  3. Set the security policy and, if required, the credentials (OPCUA_USERNAME / OPCUA_PASSWORD, i.e. the IOT_USERNAME / IOT_PASSWORD you set) and click Connect.

    On first connect the client and server exchange certificates. If the UA Cloud Publisher connection is rejected, trust its certificate in the OPC UA device and retry.

  4. Browse the device's address space and select the variable nodes you want to publish and click the 'publish' button.
  5. The Publisher immediately begins sending OPC UA PubSub JSON messages to Mosquitto (data/#), and the metadata describing each dataset to the metadata topic. Confirm data is flowing by checking the InfluxDB mqtt bucket (see Querying Data in the InfluxDB Dashboard).

Onboarding a Non-OPC UA Device

The UA Edge Translator uses W3C Web of Things (WoT) Thing Descriptions (TDs) to model a non-OPC UA asset (e.g. Modbus TCP, LoRaWAN, OCPP, or an HTTP/REST device) and expose its data points as OPC UA nodes. Once mapped, the device is published exactly like a native OPC UA device.

  1. Open the UA Cloud Publisher UI at http://<device-ip>:8081 (log in with the IOT_USERNAME / IOT_PASSWORD you set, exposed via the manifest PUBLISHER_USERNAME / PUBLISHER_PASSWORD env vars).

  2. Go to UA Edge Translator and provide a WoT Thing Description for your asset. The Thing Description declares:

    • the protocol binding (e.g. modbus+tcp://<device-ip>:502, an OCPP/ LoRaWAN endpoint, or an HTTP base URL),
    • the device's properties/telemetry (each becomes an OPC UA variable), and
    • the datatype, access, and addressing (e.g. Modbus register/coil, unit id) for each property.

    If your device vendor didn't supply a Thing Description, see Generating WoT Thing Descriptions from PLC Engineering Tools. and Generating a WoT Thing Description for a Foxed-Function Asset on how to generate a Thing Description.

    Uploaded TDs are persisted on the Pi under /translator/settings. The Edge Translator connects to the asset over its native protocol and instantiates the mapped data points as OPC UA nodes in its address space (served at opc.tcp://<device-ip>:4840).

    All asset tags specified in the Thing Description as properties are automatically published.

Querying Data in the InfluxDB Dashboard

InfluxDB 2.x includes a built-in UI with a Data Explorer and Dashboards that query data using the Flux language.

  1. Browse to http://<device-ip>:8086 and sign in with the IOT_USERNAME / IOT_PASSWORD you set.
  2. Go to Data Explorer (the graph icon) to build and preview queries, or Dashboards → Create Dashboard → Add Cell to pin a query to a dashboard.
  3. Data written by Telegraf lands in the mqtt bucket under the measurements opcua_pubsub (live values) and opcua_metadata (schema/metadata).

Example Flux query (paste into a Data Explorer / dashboard cell in Script Editor mode). This joins the live opcua_pubsub data with the opcua_metadata schema on datasetWriterId so each series is labelled with its human-readable metadata name:

data =
  from(bucket: "mqtt")
    |> range(start: v.timeRangeStart, stop: v.timeRangeStop)
    |> filter(fn: (r) =>
      r._measurement == "opcua_pubsub" and
      r._field == "Payload_VoltageL-N_Value_C"
    )
    |> keep(columns: ["_time", "_value", "datasetWriterId"])
    |> group(columns: ["datasetWriterId"])
    |> sort(columns: ["_time"])

meta =
  from(bucket: "mqtt")
    |> range(start: -30d)
    |> filter(fn: (r) =>
      r._measurement == "opcua_metadata" and
      r._field == "cfgMajor"
    )
    |> group(columns: ["datasetWriterId"])
    |> last()
    |> keep(columns: ["datasetWriterId", "metaName"])
    |> group(columns: ["datasetWriterId"])

join(tables: {d: data, m: meta}, on: ["datasetWriterId"], method: "inner")
  |> map(fn: (r) => ({
      _time: r._time,
      _value: float(v: r._value),
      _source: r.datasetWriterId,
      _tagName: r.metaName
  }))

Tip: Use the Data Explorer's visual Query Builder to discover the exact _field names available (they mirror the OPC UA PubSub payload keys, e.g. Payload_<NodeName>_Value), then switch to the Script Editor to refine the Flux and save the cell to a dashboard. Set the cell's refresh interval and time range at the top of the dashboard for live monitoring.

Dashboards with Grafana

Grafana is deployed by iot-stack.yaml as an alternative to InfluxDB's built-in dashboards, with richer visualization, templating, and alerting. It comes pre-provisioned so no manual setup is needed beyond logging in.

What the manifest provisions automatically:

  • InfluxDB data source (grafana-datasources ConfigMap) — points at http://influxdb.default.svc.cluster.local:8086 using the Flux query language, org iot, and default bucket mqtt. The query token is injected from the influxdb-auth Secret via the INFLUX_TOKEN environment variable (interpolated into the provisioned data source at startup).
  • Dashboard provider (grafana-dashboard-provider ConfigMap) — loads any dashboards found under /var/lib/grafana/dashboards.
  • Starter dashboard (grafana-dashboards ConfigMap) — OPC UA Telemetry Overview (uid opcua-overview) with a time-series panel of opcua_pubsub values, an ingest-rate stat, an active-dataset-writers stat, and a publisher template variable for filtering.

Usage:

  1. Browse to http://<device-ip>:3000 and log in with your IOT_USERNAME / IOT_PASSWORD (Grafana admin credentials set via GF_SECURITY_ADMIN_USER / GF_SECURITY_ADMIN_PASSWORD).
  2. Open Dashboards → OPC UA Telemetry Overview to see live data flowing from the mqtt bucket.
  3. Use the InfluxDB data source in Explore or when adding new panels; write Flux queries exactly as in the InfluxDB dashboard section.
  4. Grafana settings and any dashboards you create are persisted on the Pi at /grafana. (The provisioned data source and starter dashboard are managed by the ConfigMaps and re-applied on restart.)

Note: the starter dashboard's numeric time-series panel assumes numeric fields (e.g. Payload_<NodeName>_Value). Adjust the panel's Flux filter to match the exact _field names your assets publish.

Importing an OPC UA Information Model into InfluxDB (UA Cloud Library)

You can pre-load the full set of variables an OPC UA server could expose — not just the ones currently being published — by importing its Information Model from the OPC Foundation UA Cloud Library into InfluxDB.

Each model variable is written as a placeholder point (field status="[Future]") into a dedicated opcua_model measurement in the mqtt bucket, so you can see every potential node alongside the live opcua_pubsub values.

A separate measurement is used (rather than mixing into opcua_pubsub) because InfluxDB fields are single-typed — the model's placeholder is a string, while live telemetry values are numeric.

The importer is provided as an on-demand Kubernetes Job in import-opcua-model.yaml. It uses a small standard-library Python script that downloads the model's NodeSet2 XML from the Cloud Library REST API, extracts every UAVariable, and writes them to InfluxDB using the token from the existing influxdb-auth Secret.

Steps:

  1. Register (free) at the UA Cloud Library and note the model id of the model you want (visible in its Explorer URL — e.g. the Station nodeset is 1627266626).

  2. Run the import Job, supplying your Cloud Library credentials and the model id (substituted at apply time):

    export UACLOUDLIB_USERNAME="myUser"
    export UACLOUDLIB_PASSWORD="myPass"
    export UACLOUDLIB_MODEL_ID="1627266626"
    kubectl delete job import-opcua-model --ignore-not-found
    envsubst < import-opcua-model.yaml | kubectl apply -f -
    kubectl logs -f job/import-opcua-model

    The log prints how many variables were imported.

  3. Query the imported model in the InfluxDB Data Explorer or Grafana:

    from(bucket: "mqtt")
      |> range(start: -1h)
      |> filter(fn: (r) => r._measurement == "opcua_model")
      |> filter(fn: (r) => r._field == "displayName")
      |> keep(columns: ["_value", "nodeId", "dataType", "namespaceUri", "model"])
    

The Cloud Library endpoint (uacloudlibrary.opcfoundation.org) must be reachable from the cluster for the import Job to run. The Job auto-cleans up one hour after completion (ttlSecondsAfterFinished).

Command & Control with UA Cloud Commander

While the Publisher → Telegraf → InfluxDB path handles read-only telemetry, UA Cloud Commander adds a command & control path so a cloud (or local) application can remotely read, write, call methods on, and historically read OPC UA nodes on the edge — all over the same Mosquitto broker.

Cloud Commander implements the OPC UA PubSub Actions request/response pattern (OPC 10000-14). It acts as the Responder: it subscribes to the commands/# topic, executes the requested OPC UA operation against an on-premises OPC UA server (e.g. the Edge Translator at opc.tcp://<device-ip>:4840), and publishes the result to the responses topic.

How It Is Configured

ua-cloudcommander is deployed by iot-stack.yaml and connects to Mosquitto via these environment variables (no web UI — it is configured entirely through env):

Variable Value Purpose
BROKERNAME mosquitto.default.svc.cluster.local In-cluster Mosquitto Service.
BROKERPORT 8883 TLS MQTT port.
USE_TLS true Mosquitto requires TLS.
CLIENTNAME UACloudCommander MQTT client id / Responder PublisherId.
TOPIC commands/# Topic it subscribes to for ua-action-request messages.
RESPONSE_TOPIC responses Default topic for ua-action-response messages (used when a request omits ResponseAddress).
USERNAME / PASSWORD ${IOT_USERNAME} / ${IOT_PASSWORD} Broker credentials (same as the rest of the stack).
UA_USERNAME / UA_PASSWORD ${IOT_USERNAME} / ${IOT_PASSWORD} Credentials used to sign in to the target OPC UA servers.

The OPC UA client certificate and logs are persisted on the Pi under /commander/pki and /commander/logs.

Self-signed TLS: Mosquitto uses a self-signed certificate generated at pod startup. If Cloud Commander rejects the TLS handshake, mount/trust the broker's CA certificate in the Commander container (or use a trusted-CA certificate for Mosquitto) as recommended in the security note above.

Sending a Command

Publish a ua-action-request NetworkMessage to the commands topic and listen on responses for the reply. For example, to read a node (from a machine that can reach the broker, using the stack credentials over TLS):

# Subscribe for responses in one terminal
mosquitto_sub -h <device-ip> -p 8883 --cafile ca.crt \
  -u "$IOT_USERNAME" -P "$IOT_PASSWORD" -t responses

# Publish a Read request in another terminal
mosquitto_pub -h <device-ip> -p 8883 --cafile ca.crt \
  -u "$IOT_USERNAME" -P "$IOT_PASSWORD" -t commands -m '{
    "MessageId": "32235f26-4a3a-4a56-9f1f-2b6f8a2f0a11",
    "MessageType": "ua-action-request",
    "PublisherId": "MyCloudApp",
    "Timestamp": "2022-11-28T12:01:00.0923534Z",
    "RequestorId": "MyCloudApp",
    "TimeoutHint": 15000,
    "Messages": [
      {
        "DataSetWriterId": 1,
        "ActionTargetId": 1,
        "RequestId": 1,
        "ActionState": 1,
        "Payload": {
          "Endpoint": "opc.tcp://<device-ip>:4840",
          "NodeId": "http://opcfoundation.org/UA/Station/;i=123"
        }
      }
    ]
  }'

The ActionTargetId selects the operation: 1 = Read, 2 = HistoricalRead, 3 = Write, 4 = MethodCall. Cloud Commander replies on responses with a ua-action-response message echoing RequestorId / RequestId and containing the Result (or an Error). See the UA Cloud Commander documentation for the full payload schema of each operation.

Automated Feedback Loop with UA Cloud Action

UA Cloud Action is the automated Requestor counterpart to Cloud Commander. Instead of a human publishing a command, it polls telemetry and reacts: on a 15-second loop it queries a configured value and, when it crosses a threshold, publishes a ua-action-request (a MethodCall) to the commands topic — which Cloud Commander executes on the target OPC UA server. This closes an edge-local digital feedback loop entirely on the Pi.

In this reference stack it is deployed (iot-stack.yaml) to read from InfluxDB and drive Commander over Mosquitto:

Variable Value Purpose
DATA_SOURCE InfluxDB Use InfluxDB as the trigger source (instead of Azure Data Explorer).
INFLUX_URL http://influxdb.default.svc.cluster.local:8086 InfluxDB endpoint.
INFLUX_ORG / INFLUX_BUCKET iot / mqtt Org and bucket to query.
INFLUX_MEASUREMENT opcua_pubsub Measurement to query.
INFLUX_FIELD Payload_Pressure_Value Numeric field to evaluate — change to match your assets.
INFLUX_THRESHOLD 4000 Trigger when the latest value exceeds this.
INFLUX_RANGE -1m Look-back window for the latest value.
INFLUX_TOKEN (from influxdb-auth) Query token.
MESSAGING_PLATFORM MQTT Reach Commander over MQTT (not Kafka).
MQTT_TARGET UACloudCommander Send the full OPC UA PubSub ActionRequest envelope.
BROKER_NAME / MQTT_PORT mosquitto… / 8883 Mosquitto broker (TLS).
MQTT_USE_TLS / MQTT_TLS_INSECURE true / true TLS with the self-signed broker cert (verification skipped, like Telegraf).
BROKER_USERNAME / BROKER_PASSWORD ${IOT_USERNAME} / ${IOT_PASSWORD} Broker credentials.
TOPIC / RESPONSE_TOPIC commands / responses The topics Cloud Commander subscribes/replies on.
UA_SERVER_ENDPOINT, UA_SERVER_METHOD_ID, UA_SERVER_OBJECT_ID, … (placeholders) The OPC UA method Cloud Commander invokes on trigger — set these to a real method on your target server (e.g. the Edge Translator).

InfluxDB data source: support for querying InfluxDB was added to UA Cloud Action for this stack (the upstream app queries Azure Data Explorer). The DATA_SOURCE=InfluxDB branch runs a Flux query for the latest INFLUX_FIELD value and compares it to INFLUX_THRESHOLD. Set INFLUX_FIELD to a numeric field your assets actually publish (discover exact names in the InfluxDB Data Explorer or Grafana), otherwise no trigger will fire.

A small status UI is available at http://<device-ip>:8082 (log in with your IOT_USERNAME / IOT_PASSWORD), showing connectivity to the data source, the broker, and Cloud Commander.

Accessing the OPC UA Web API (UA Cloud Action)

In addition to the MQTT-based feedback loop, UA Cloud Action exposes an OPC UA Web API — a RESTful, OpenAPI-based HTTP interface to the standard OPC UA services defined in OPC UA Part 4. This lets you build custom applications — dashboards, mobile apps, analytics jobs, or backend integrations — that talk to the edge's OPC UA servers over plain HTTP/JSON, without embedding a native OPC UA stack.

Implemented services: this reference deployment implements the Read, HistoryRead (historical read), and Browse services of the OPC UA Web API. Other services (Write, Call, etc.) are not implemented due to security considerations — requests to them are not available. Use UA Cloud Commander (the MQTT command path) for Write/Call operations in the meantime.

Note: the Web API is being implemented in UA Cloud Action. The endpoints and auth described below track the OPC UA Web API specification; confirm the exact routes against the running service's OpenAPI/Swagger document.

Reaching the Web API

The API is served by the ua-cloudaction container and reachable through its Service at:

http://<device-ip>:8082
  • The OpenAPI/Swagger definition (e.g. http://<device-ip>:8082/swagger) describes every available route and schema — point your tooling at it to explore or generate clients. In the interactive Swagger UI, use the Authorize button to supply the Basic credentials before invoking the /opcua/read and /opcua/historyread operations.
  • Authentication is mandatory. The UA Cloud Action web UI and Web API require HTTP Basic authentication on every request — there is no anonymous access. Supply the IOT_USERNAME / IOT_PASSWORD credentials (set via the manifest's ADMIN_USERNAME / ADMIN_PASSWORD) in the HTTP Authorization: Basic <base64> header. Unauthenticated requests receive 401 Unauthorized with a WWW-Authenticate: Basic challenge.

    The OPC UA Web API specification also allows bearer/JWT tokens in the Authorization header (the reference gateway uses OAuth2 JWTs); Basic auth is what this reference deployment mandates.

  • The API is rate limited per client IP using a fixed window. The limit and window are configurable via the RATE_LIMIT_PERMIT and RATE_LIMIT_WINDOW_SECONDS environment variables (defaulting to 60 requests per 60 seconds in iot-stack.yaml). Requests exceeding the limit receive 429 Too Many Requests.
  • Behind the OPC UA Web API, UA Cloud Action forwards the requested service to the target OPC UA server (e.g. the Edge Translator at opc.tcp://ua-edgetranslator.default.svc.cluster.local:4840).

Building Custom Apps with the Starter Kit

Use the OPC Foundation UA Web API Starter Kit as the starting point. Its UaWebApiClient folder contains ready-to-run sample clients in several environments that call the OPC UA Web API using pre-built stubs (classes/constants for the OPC UA services, BrowseNames, and NodeIds):

Sample client Language / stubs
UaWebApiClient/csharp C# — DotNet stubs
UaWebApiClient/nodejs JavaScript — TypeScript stubs
UaWebApiClient/react TypeScript (browser) — TypeScript stubs
UaWebApiClient/python Python — Python stubs

Typical workflow to build your own app:

  1. Clone the starter kit and pick the sample client that matches your stack:
    git clone https://github.com/OPCFoundation/UA-WebApi-StarterKit.git
    cd UA-WebApi-StarterKit/UaWebApiClient
  2. Point the client at your Web API endpoint — set its base URL to http://<device-ip>:8082 (the UA Cloud Action Web API) and set the Authorization: Basic <base64(user:pass)> header (mandatory) using your IOT_USERNAME / IOT_PASSWORD.
  3. Use the pre-built stubs to invoke OPC UA services with typed requests/responses instead of hand-crafting JSON. In this deployment the available operations are Read, HistoryRead, and Browse (reading current and historical variable values and browsing the address space); Write and Call are not yet exposed by the Web API.
  4. (Optional) Generate model-specific classes. For DataTypes from a custom information model, convert its NodeSet to an OpenAPI schema with the Opc.Ua.ModelCompiler, then generate typed classes with the OpenAPI Generator — exactly as the starter kit does — so your app understands the model's structured values.
  5. Iterate from a sample — start from the closest UaWebApiClient sample and extend it into your own dashboard, service, or integration.

Because the interface is standard OpenAPI, you can also generate a client in any other language supported by the OpenAPI Generator directly from the service's OpenAPI document, rather than using the pre-built stubs.

Security Analysis (STRIDE)

This section applies the STRIDE threat-modeling framework (Spoofing, Tampering, Repudiation, Information disclosure, Denial of service, Elevation of privilege) to the reference stack. It is intended to help you understand the residual risks of the demo configuration and what to change before an internet-exposed or production deployment.

Important: the reference manifest is optimized for a self-contained, single-node demo. It ships with convenience defaults (shared credentials, a self-signed broker certificate generated at pod start, LoadBalancer services bound to the node IP, and permissive TLS verification in Telegraf). These are not appropriate for production as-is — see Production Hardening Recommendations.

Trust Boundaries and Assets

[Field devices] --(OPC UA / Modbus / LoRaWAN / OCPP / HTTP)--> [UA Edge Translator]
      |                                                                |
      |  Boundary A: device <-> edge                                   | (OPC UA server :4840)
      v                                                                v
[UA Cloud Publisher] --(MQTT/TLS :8883, user/pass)--> [Mosquitto] --(MQTT/TLS)--> [Telegraf] --(HTTP + token)--> [InfluxDB]
      ^                                                  ^   ^                                                        ^   ^
      |                            [UA Cloud Commander] -+   |  (commands/responses)                                  |   |
      |                            [UA Cloud Action] --------+--(reads InfluxDB threshold, publishes commands)--------+   |
      |                                                                                                    [Grafana] -----+ (query token)
      |                                                                                          [Model importer Job] ----+ (writes opcua_model)
      |  Boundary B: operator <-> web UIs (:8080/:8081/:8082/:8086/:3000/:9443, basic auth)                                |
      +----------- Boundary C: node/cluster host (K3s + Portainer cluster-admin, hostPath volumes) -----------------------+

Key assets: the telemetry data (in transit and at rest in InfluxDB), the shared IOT_USERNAME / IOT_PASSWORD credentials, the INFLUX_TOKEN, the UA Cloud Library credentials used by the import Job, the broker's private key, the Portainer cluster-admin ServiceAccount token (full control of the cluster), and the K3s node itself (root of trust for all hostPath data).

STRIDE Threat Assessment

STRIDE category Representative threats in this stack Mitigations already in place Residual risk / gaps
Spoofing (identity) A rogue client impersonates the Publisher or UA Cloud Commander/Action to the broker; an attacker impersonates a web UI user (Translator, Publisher, Grafana, UA Cloud Action, or Portainer); a fake OPC UA server feeds the Publisher; a forged ua-action-request triggers an OPC UA method; an unauthenticated caller hits the OPC UA Web API. MQTT broker requires username/password (allow_anonymous false); all web UIs (:8080/:8081/:8082/:3000/:9443) require login; the UA Cloud Action web UI and OPC UA Web API mandate HTTP Basic authentication on every request (no anonymous access); OPC UA supports certificate exchange between Publisher/Commander and server. Single shared credential set across all components (including Grafana/Portainer admin and the Web API); Basic-auth credentials are only as safe as the transport (send over TLS in production); no per-service identities or mutual TLS (mTLS); broker does not authenticate clients by certificate; any client that can publish to commands can drive Commander.
Tampering (integrity) Modification of telemetry in transit; tampering with hostPath config/cert files on the node; editing the ConfigMaps; altering the imported opcua_model data or the model importer script; a malicious command writing/actuating an OPC UA node via Commander. MQTT is carried over TLS (8883); config is delivered via Kubernetes ConfigMaps/Secrets; Commander/Action send spec-compliant OPC UA PubSub Action envelopes. Telegraf and UA Cloud Action use TLS verification skip (insecure_skip_verify / MQTT_TLS_INSECURE=true), so a man-in-the-middle with any cert is accepted; hostPath volumes (/influxdb2, /translator/*, /publisher/*, /commander/*, /portainer, /grafana) are writable by anyone with node access; no message signing on payloads; Commander performs Writes/MethodCalls with no per-action authorization.
Repudiation (auditability) An operator changes a device mapping, publish set, Grafana dashboard, or issues a command and denies it; no record of who logged in or who imported a model. Component logs are written to hostPath logs directories and pod stdout; Portainer records some cluster events. No centralized, tamper-evident audit log; shared credentials make actions unattributable to an individual; command/action requests and model imports are not attributably logged; no log shipping or retention policy.
Information disclosure (confidentiality) Sniffing telemetry; reading credentials from the manifest; exposed dashboards (Grafana, Portainer, UA Cloud Action) on the node IP; leaking the UA Cloud Library credentials used by the import Job. MQTT is encrypted with TLS; INFLUX_TOKEN is stored in a Kubernetes Secret; credentials are supplied at apply time (not committed to git). Credentials (including UA Cloud Library and Grafana/Portainer admin) are injected as plain-text env vars (visible via kubectl describe/exec); Kubernetes Secrets are base64, not encrypted at rest by default; self-signed broker cert offers encryption but no server-identity assurance; all UIs are exposed on the node IP with no network policy.
a single node is a single point of failure; broker persists to hostPath (/mosquitto), reducing message loss on restart though the single node remains a SPOF; UA Cloud Action's rate limit still needs tuning for your environment.
Elevation of privilege (authorization) Container escape to the node; a compromised pod reading another component's data via shared host paths; using the InfluxDB admin token for full DB control; abusing Portainer's cluster-admin ServiceAccount to take over the whole cluster; using Commander/Action to reach and control OT devices. Distinct container images per component; nodeSelector pins workloads to Linux; the importer Job uses restartPolicy: Never. Containers run with default (often root) user and no securityContext; no NetworkPolicy isolation between pods; the InfluxDB token is an all-powerful admin token; Portainer is bound to cluster-admin, so compromising it compromises the cluster; Commander bridges IT→OT with method-call/write capability and no fine-grained authorization; no RBAC scoping for the workloads.

Production Hardening Recommendations

The following changes move the stack from a demo toward a production-grade deployment. Prioritize the items marked (High).

  1. Use unique, per-service credentials (High). Replace the single shared IOT_USERNAME / IOT_PASSWORD with distinct identities for the Translator UI, Publisher UI, broker client, and InfluxDB admin. Store them in a real secrets manager (e.g. HashiCorp Vault, Sealed Secrets, or an external secrets operator) rather than plain-text env vars.
  2. Deploy trusted TLS certificates and enforce verification (High). Replace the self-signed, pod-generated broker certificate with one from a trusted CA (e.g. via cert-manager). Remove insecure_skip_verify = true from the Telegraf MQTT inputs and pin the broker CA so man-in-the-middle attacks are prevented. Enable TLS on the web UIs (terminate at an ingress).
  3. Enable mutual TLS (mTLS) or per-client auth on the broker. Configure Mosquitto to authenticate publishers/subscribers by client certificate in addition to username/password, and use ACLs to restrict which topics each client may publish/subscribe to.
  4. Scope the InfluxDB token (High). Do not use the all-powerful admin token for Telegraf. Create a dedicated write-only token limited to the mqtt bucket, and separate read tokens for dashboards.
  5. Restrict network exposure (High). Do not expose LoadBalancer services directly on the node IP. Front the web UIs with an authenticating reverse proxy/ingress, place the broker and database on an internal network only, and add Kubernetes NetworkPolicy rules so pods can only reach the peers they need.
  6. Harden the pods. Add a securityContext (runAsNonRoot: true, readOnlyRootFilesystem: true, drop Linux capabilities, allowPrivilegeEscalation: false) and set CPU/memory requests/limits to contain resource-exhaustion and blast radius.
  7. Protect data at rest. Enable encryption at rest for the node's disk (/influxdb2 and the other hostPath volumes) and for Kubernetes Secrets (e.g. a KMS provider or an encrypted etcd). Replace ad-hoc hostPath volumes with managed PersistentVolumeClaims where possible.
  8. Add auditing and monitoring. Ship component and access logs to a central, tamper-evident store; enable Kubernetes audit logging; and add alerting on authentication failures, pod restarts, and disk usage.
  9. Manage capacity and availability. Set InfluxDB retention policies to bound growth, back up /influxdb2 regularly, and consider multi-node/HA for the broker and database to remove the single-point-of-failure.
  10. Keep software patched. Pin and regularly update the container image versions, apply OS/K3s security updates, and scan images for known vulnerabilities as part of your release process.
  11. Scope Portainer's cluster access (High). The demo binds Portainer to the built-in cluster-admin role. For production, grant it a least-privilege Role/ClusterRole limited to the namespaces and resources operators actually manage, protect its UI behind the ingress, and enforce strong, per-user Portainer accounts (not the shared credentials).
  12. Authorize and throttle the command/control path. Restrict who can publish to the commands topic (broker ACLs) and validate/allow-list the OPC UA methods and nodes UA Cloud Commander may Write/Call. UA Cloud Action includes a built-in rate limiter on its actuation, so a faulty threshold or spoofed value cannot drive OT devices uncontrollably; tune its limit for your environment. Treat the UA Cloud Library import credentials as secrets and restrict the import Job's egress.