Configuration Guide

Configuration Model

IOBusMonitor is configured around this hierarchy:

Device
└── Point
    └── Measurement

Device

A device defines the communication endpoint.

Protocol-specific fields currently visible in the codebase:

  • Modbus TCP: device name, IP/host, port, active state
  • Modbus RTU: device name, serial port, baud rate, parity, slave ID, active state
  • Siemens S7: device name, IP/host, port, rack, slot, CPU type, active state

Validation behavior currently implemented:

  • device name is required,
  • endpoint fields must be valid,
  • names must be unique,
  • protocol endpoint combinations must be unique within the same protocol table.

Point

A point is a logical group under one device. Typical examples:

  • station,
  • skid,
  • controller section,
  • process area.

Validation behavior currently implemented:

  • point name is required,
  • referenced device must exist,
  • point names must be unique per device.

Measurement

A measurement defines one value source under a point.

Current measurement fields depend on protocol but generally include:

  • name,
  • engineering unit,
  • register or address,
  • quantity or data width,
  • rounding,
  • condition/formula,
  • active state.

Validation behavior currently implemented:

  • measurement name is required,
  • referenced point must exist,
  • Modbus register must be zero or greater,
  • Modbus quantity must be 1, 2, or 4,
  • rounding must be between 0 and 6,
  • Siemens addresses must match formats such as DB1.DBX0.0, DB1.DBB0, DB1.DBW2, DB1.DBD4, DB1.DBL8,
  • names must be unique per point,
  • register/address combinations must be unique per point.

Condition / Formula Field

The current admin validation requires a condition string for each measurement.

For a pass-through measurement, use:

value

If the expression is invalid, the admin workflow rejects the row before save.

Application Settings

The app settings page currently persists:

  • read interval in milliseconds,
  • auto start,
  • demo mode enabled/disabled,
  • data path for daily SQLite archives.

Defaults currently documented from code:

  • read interval: 1000 ms
  • auto start: false
  • default data path: <app folder>\Data

Data Location

The settings database is created under:

Settings/Settings.db

Daily measurement archives are written under:

Data/Data_yyyyMMdd.db

If PathData is changed in app settings, daily archives are written to that configured folder instead of the default local Data folder.